Data Center Power Generation and Microgrids Engineer
anthropic
1 day ago
Full-time
On-site
Remote-Friendly, United States
$320,000 - $405,000 USD yearly
Engineering
Moneyboard classification: Published base at/above threshold
Reported USD annual base: $320,000β$405,000
Original source: Greenhouse
About Anthropic
Anthropicβs mission is to create reliable, interpretable, and steerable AI systems. We want AI to be safe and beneficial for our users and for society as a whole. Our team is a quickly growing group of committed researchers, engineers, policy experts, and business leaders working together to build beneficial AI systems.
About the role
Training and serving frontier AI models requires compute infrastructure at a scale and density that pushes past what conventional data center designs were built to handle. The loads involved are large enough β and arrive fast enough β that utility supply alone often can't meet the need on the timeline required, and the step-load behavior of large accelerator clusters creates power-quality and ride-through demands that conventional backup-generation designs weren't built for. Anthropic's Data Center Infrastructure team is responsible for solving that problem: delivering facilities that can be energized early, ride through grid disturbances, and present a well-behaved load at the point of interconnection (POI).
Β
As a Data Center Power Generation & Microgrids Engineer, you'll own the behind-the-meter generation and storage architecture for Anthropic's data center portfolio. That means the on-site generation fleet β reciprocating engine gensets, gas turbines, fuel cells β and the battery energy storage systems that buffer load steps and provide ride-through. It means the microgrid layer that ties them together: islanding and resynchronization, black-start, load-shedding, and generation dispatch. And it means the grid side: interconnection studies and agreements, IEEE 1547/2800 compliance, and power quality at the point of interconnection. You'll also own our temporary- and bridging-generation strategies β the plans that let a site energize and start serving load before permanent utility service is available, and transition cleanly once it is.
This is a deeply cross-functional role. You'll work closely with colleagues across the infrastructure team on where and how generation and storage tie into the site electrical distribution, controls, and SCADA, and with our hardware and compute teams to understand the load characteristics you're designing against. You'll be Anthropic's technical counterpart to on-site generation providers, BESS integrators, utilities, and ISOs/RTOs. Expect roughly 20β35% travel for design reviews, factory witness testing, and site startup.
Responsibilities
On-site generation engineering
Own Anthropic's behind-the-meter generation architecture across the portfolio β prime-mover selection and sizing (reciprocating engines, gas turbines, fuel cells), paralleling topology, redundancy, fuel systems, and emissions controls β and maintain the generation basis of design and technical specifications that build partners and generation providers design against
Set the day-one vs. day-N plant sizing and expansion strategy β what the plant needs on day one so it can be expanded or augmented later, and how to add units, storage, or a grid tie to a system already running
Characterize the data center load for external generation partners β step changes, ramps, oscillation, fault behavior, and non-IT load β so providers can size and tune their plant against the real duty
Model generation response against the load profile of large-scale ML training β step-load acceptance, block loading, transient frequency and voltage response, load rejection β and set the acceptance criteria (e.g., per ISO 8528-5) that generation packages are tested against
Develop temporary- and bridging-generation strategies that deliver early site energization ahead of permanent utility service, including the sequencing, protection, and controls changes needed to transition from temporary to permanent power without stranding equipment or capacity
Ensure generation designs meet NFPA 37, NFPA 110 where the plant provides emergency or legally required standby power, fuel-gas and fuel-storage codes (e.g., NFPA 54, NFPA 30), and applicable emissions requirements, and coordinate with environmental and permitting counterparts on the technical inputs to air permits
Energy storage & microgrid architecture
Size and specify battery energy storage systems for ride-through, step-load buffering, and power-quality support β including cell chemistry and enclosure selection, inverter selection (grid-forming vs. grid-following), UL 9540 listing, UL 9540A large-scale fire test data, and NFPA 855 installation requirements β and own the thermal and fire-protection interfaces
Define the site microgrid topology and operating modes β grid-parallel, islanded, and black-start β and the transition logic between them, including load-shedding schemes, resynchronization criteria, and the conditions under which the site separates from and reconnects to the utility
Specify the functional requirements for the microgrid controller β generation dispatch, set-point coordination across rotating and inverter-based sources, mode management β and drive its implementation, testing, and integration into site SCADA and the electrical power monitoring system (EPMS)
Help define the protection and control requirements for generation and storage sources so that interconnection protection, anti-islanding, and source-transfer schemes are consistent from the generator terminals through the point of interconnection
Grid interconnection & power quality
Lead the technical side of utility interconnection for sites with on-site generation or storage β interconnection applications, studies, and agreements, ISO/RTO processes, IEEE 1547/2800 compliance, and interconnection protection
Own power quality at the point of interconnection β flicker per IEEE 1453, harmonics per IEEE 519, voltage regulation, reactive-power and power-factor requirements β and design the generation, storage, and filtering mitigations needed to keep the site within its interconnection limits under real training-load behavior
Run or
Reported USD annual base: $320,000β$405,000
Original source: Greenhouse
About Anthropic
Anthropicβs mission is to create reliable, interpretable, and steerable AI systems. We want AI to be safe and beneficial for our users and for society as a whole. Our team is a quickly growing group of committed researchers, engineers, policy experts, and business leaders working together to build beneficial AI systems.
About the role
Training and serving frontier AI models requires compute infrastructure at a scale and density that pushes past what conventional data center designs were built to handle. The loads involved are large enough β and arrive fast enough β that utility supply alone often can't meet the need on the timeline required, and the step-load behavior of large accelerator clusters creates power-quality and ride-through demands that conventional backup-generation designs weren't built for. Anthropic's Data Center Infrastructure team is responsible for solving that problem: delivering facilities that can be energized early, ride through grid disturbances, and present a well-behaved load at the point of interconnection (POI).
Β
As a Data Center Power Generation & Microgrids Engineer, you'll own the behind-the-meter generation and storage architecture for Anthropic's data center portfolio. That means the on-site generation fleet β reciprocating engine gensets, gas turbines, fuel cells β and the battery energy storage systems that buffer load steps and provide ride-through. It means the microgrid layer that ties them together: islanding and resynchronization, black-start, load-shedding, and generation dispatch. And it means the grid side: interconnection studies and agreements, IEEE 1547/2800 compliance, and power quality at the point of interconnection. You'll also own our temporary- and bridging-generation strategies β the plans that let a site energize and start serving load before permanent utility service is available, and transition cleanly once it is.
This is a deeply cross-functional role. You'll work closely with colleagues across the infrastructure team on where and how generation and storage tie into the site electrical distribution, controls, and SCADA, and with our hardware and compute teams to understand the load characteristics you're designing against. You'll be Anthropic's technical counterpart to on-site generation providers, BESS integrators, utilities, and ISOs/RTOs. Expect roughly 20β35% travel for design reviews, factory witness testing, and site startup.
Responsibilities
On-site generation engineering
Own Anthropic's behind-the-meter generation architecture across the portfolio β prime-mover selection and sizing (reciprocating engines, gas turbines, fuel cells), paralleling topology, redundancy, fuel systems, and emissions controls β and maintain the generation basis of design and technical specifications that build partners and generation providers design against
Set the day-one vs. day-N plant sizing and expansion strategy β what the plant needs on day one so it can be expanded or augmented later, and how to add units, storage, or a grid tie to a system already running
Characterize the data center load for external generation partners β step changes, ramps, oscillation, fault behavior, and non-IT load β so providers can size and tune their plant against the real duty
Model generation response against the load profile of large-scale ML training β step-load acceptance, block loading, transient frequency and voltage response, load rejection β and set the acceptance criteria (e.g., per ISO 8528-5) that generation packages are tested against
Develop temporary- and bridging-generation strategies that deliver early site energization ahead of permanent utility service, including the sequencing, protection, and controls changes needed to transition from temporary to permanent power without stranding equipment or capacity
Ensure generation designs meet NFPA 37, NFPA 110 where the plant provides emergency or legally required standby power, fuel-gas and fuel-storage codes (e.g., NFPA 54, NFPA 30), and applicable emissions requirements, and coordinate with environmental and permitting counterparts on the technical inputs to air permits
Energy storage & microgrid architecture
Size and specify battery energy storage systems for ride-through, step-load buffering, and power-quality support β including cell chemistry and enclosure selection, inverter selection (grid-forming vs. grid-following), UL 9540 listing, UL 9540A large-scale fire test data, and NFPA 855 installation requirements β and own the thermal and fire-protection interfaces
Define the site microgrid topology and operating modes β grid-parallel, islanded, and black-start β and the transition logic between them, including load-shedding schemes, resynchronization criteria, and the conditions under which the site separates from and reconnects to the utility
Specify the functional requirements for the microgrid controller β generation dispatch, set-point coordination across rotating and inverter-based sources, mode management β and drive its implementation, testing, and integration into site SCADA and the electrical power monitoring system (EPMS)
Help define the protection and control requirements for generation and storage sources so that interconnection protection, anti-islanding, and source-transfer schemes are consistent from the generator terminals through the point of interconnection
Grid interconnection & power quality
Lead the technical side of utility interconnection for sites with on-site generation or storage β interconnection applications, studies, and agreements, ISO/RTO processes, IEEE 1547/2800 compliance, and interconnection protection
Own power quality at the point of interconnection β flicker per IEEE 1453, harmonics per IEEE 519, voltage regulation, reactive-power and power-factor requirements β and design the generation, storage, and filtering mitigations needed to keep the site within its interconnection limits under real training-load behavior
Run or